University Library of Freiburg

Location

Freiburg im Breisgau / Germany

Principal Use

Cultural

Design Architect

Degelo Architekten

Anything about the engineers? Facade consultants?

IFP-Weber, Argenbühl

Gross Floor Area

41,673 m2 Units SI IP

448,569 ft2

Reason(s) for inclusion

Building Name

University Library of Freiburg

Address

Platz der Universität 2

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

The initial library, dating from the 70s showed architectural and energetic deficiencies and had to be rebuilt. By cutting away parts of the building, Degelo Architects not only reduced the disproportionately large volume of the old library, but also made the building react to its urban context. Thus the building became a cut diamond. The façade of this crystalline sculpture is composed of electrochemically treated chrome steel. The façade sees itself as an interface, which communicates between university and city.

General Information

Year completed (or major renovation)

2015

Construction Cost

61000000

Climate Zone

Continental

External Links

Link(s) for more information

Other Design Features

Energy Performance

Percentage Provided by On-site Renewables

10%

Construction Type

Construction Type

  • Curtain Wall

Prevalent Glazing Type

  • triple glazing

Main Cladding Material

  • Glass

Typical U-value Glazed Facade Elements

1 W/(m2⋅K)

0 Btu/(h·ft2⋅F)

Typical G-value Glazed Facade Elements

16%

Skin Type

Skin Type

  • Double Skin Facade

Geometrical configuration

  • Corridor

Ventilation type

  • Indoor Air Curtain
  • Open Cavity

Solar Shading

Solar Shading Strategy

  • Static Exterior Shading

Glazing-integrated shading

  • Electrochromic Glazing

Ventilation

Is there natural ventilation through the facade?

Yes

Type of Ventilation Strategy

  • Single-sided

Relationship to Mechanical Systems

  • Alternative (when natural vent is on mechanical is off)

Ventilation Operation Type

  • BMS controlled with overrides

Ventilation Control Strategy

  • Based on Indoor CO2 concentration

Area of the building that can be served solely by natural ventilation

70%

Daylight

Is daylight simulation part of the design process?

Yes

Daylight metric(s)

  • UDI

Noise

Maximum sound attenuation through the facade

-45 dB

Embodied Carbon

Was a carbon assesment of the facade conducted in the design phase?

No

Energy Generation

Does the facade produce energy?

No

Insulation

Does the facade have a dynamic U-value?

No

Active or Passive?

Monomaterial envelope?

No

Description / Additional Information