CBE Facade Map

Supporting the adoption of advanced facade design strategies and technologies

Select Page

Map

Shareable post

Ken Soble Tower

Location

Hamilton, ON, Canada

Principal Use

Residential

Design Architect

ERA Architects

Anything about the engineers? Facade consultants?

Mechanical: Reinbold Engineering Group,

Gross Floor Area

7,525 m2 Units SI IP

81,000 ft2

Reason(s) for inclusion

Building Name

Ken Soble Tower

Address

500 MacNab Street North, Hamilton, Ontario, Canada

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

Primary focus was re-using existing concrete structure to transform from leaky poor energy performance and very uncomfortable to high performance retrofit. Addition of new mechanical systems by removing all radiators and heating through ventilation, was possible due to facade upgrade. New facade and windows was kept as simple and cost effective as possible.

General Information

Year completed (or major renovation)

2021

Construction Cost

25000000

Climate Zone

Continental

Building Certifications (check all that apply)

  • EnerPHit Standard

Other Design Features

Energy Performance

Energy Use Intensity (energy consumption per year)

145 kWh/m2/year

1,561 kBtu/ft2/year

Carbon Use Intensity

1 kgCO2e/m2/year

1 kgCO2e/ft2/year

Construction Type

Construction Type

  • Massive Facade Construction

Prevalent Glazing Type

  • triple glazing

Main Cladding Material

  • Other (please specify)

Other Cladding Material

Stucco

Approximate WWR (measured from the inside)

14%

Typical U-value Glazed Facade Elements

1 W/(m2⋅K)

0 Btu/(h·ft2⋅F)

Typical G-value Glazed Facade Elements

39%

Typical VLT Glazed Facade Elements

59%

Typical U-value Solid Facade Elements

0.13 W/(m2⋅K)

0.02 Btu/(h·ft2⋅F)

Skin Type

Skin Type

  • Single Skin Facade

Solar Shading

Solar Shading Strategy

  • None

Ventilation

Is there natural ventilation through the facade?

Yes

Type of Ventilation Strategy

  • Single-sided

Relationship to Mechanical Systems

  • Assisted (both can work simultaneously)

Ventilation Operation Type

  • Manual
  • BMS controlled without overrides

Ventilation Control Strategy

  • Based on Outdoor Air Temperature
  • Manual boost available for improved thermal comfort (extra heat, cooling or fresh air)
  • Other (please specify)
  • Manual boost available for improved thermal comfort (extra heat, cooling or fresh air)

Daylight

Is daylight simulation part of the design process?

No

Noise

Embodied Carbon

Was a carbon assesment of the facade conducted in the design phase?

Yes

Energy Generation

Does the facade produce energy?

No

Insulation

Does the facade have a dynamic U-value?

No

U-value ranges

0.13

Description / Additional Information