CSU East Bay Student and Faculty Support Building

Location

Hayward, CA, United States

Principal Use

Cultural

Design Architect

LPA Inc

Anything about the engineers? Facade consultants?

LPA Inc

Gross Floor Area

75,000 m2 Units SI IP

807,300 ft2

Reason(s) for inclusion

Building Name

CSU East Bay Student and Faculty Support Building

Address

Student and Faculty Support Building, 25800 Carlos Bee Blvd, Hayward, CA 94542, United States

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

he building houses the campus Welcome Center, as well as administrative and faculty offices. The glazing pattern includes operable windows to take advantage of the pleasant coastal climate without compromising energy efficiency. Building systems are engineered with a variable air volume (VAV) system, high-efficiency condensing boilers, low-flow plumbing fixtures, PV panels and advanced lighting controls that account for daylight harvesting. Interior finishes use high recycled content. Low-VOC paints and low-odor carpets promote a healthy indoor air quality.

General Information

Year completed (or major renovation)

2015

Construction Cost

40000000

Climate Zone

Continental

Building Certifications (check all that apply)

  • LEED
  • LEED

External Links

Link(s) for more information

Other Design Features

Energy Performance

Percentage Provided by On-site Renewables

35%

Construction Type

Construction Type

  • Massive Facade Construction

Prevalent Glazing Type

  • triple glazing

Main Cladding Material

  • Concrete

Skin Type

Skin Type

  • Single Skin Facade

Solar Shading

Solar Shading Strategy

  • Static Exterior Shading

Ventilation

Is there natural ventilation through the facade?

No

Daylight

Is daylight simulation part of the design process?

No

Noise

Embodied Carbon

Was a carbon assesment of the facade conducted in the design phase?

No

Energy Generation

Does the facade produce energy?

No

Insulation

Does the facade have a dynamic U-value?

No

Description / Additional Information