CBE Facade Map

Supporting the adoption of advanced facade design strategies and technologies

Select Page

Map

Shareable post

2226 Lustenau

Location

Lustenau, Austria

Principal Use

Office

Design Architect

Baumschlager Eberle

Gross Floor Area

543 m2 Units SI IP

5,845 ft2

Reason(s) for inclusion

Building Name

2226 Lustenau

Address

6890 Lustenau, Austria

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

The building has no heating, ventilation or cooling system, the flow of energy being controlled by software. Above all, however, this is a stone building with walls, doors and high-ceilinged rooms. It needs little grey energy, and elementary architectural means are used to create a sense of well-being that derives from the pleasant proportions and self-explanatory use. The constructional and energy-related foundations needed to achieve this effect illustrate the know-how bebaumschlagereberle has built up over 28 years. The envelope has a cavity wall structure with each wall consisting of 36-ce

General Information

Year completed (or major renovation)

2013

Climate Zone

Temperate

Building Certifications (check all that apply)

  • LEED
  • Breeam

External Links

Link(s) for more information

Other Design Features

Energy Performance

Construction Type

Construction Type

  • Massive Facade Construction

Main Cladding Material

  • Concrete

Approximate WWR (measured from the inside)

20%

Skin Type

Skin Type

  • Single Skin Facade

Solar Shading

Solar Shading Strategy

  • Static Exterior Shading
  • INFO ON SOLAR?

Ventilation

Is there natural ventilation through the facade?

No

Daylight

Is daylight simulation part of the design process?

No

Noise

Embodied Carbon

Disassembly/EOL strategy

INFO ON CARBON?

Energy Generation

Insulation

Active or Passive?

Monomaterial envelope?

Yes

Description / Additional Information