CBE Facade Map

Supporting the adoption of advanced facade design strategies and technologies

Select Page

Map

Shareable post

The University of Calgary – MacKimmie Tower

Location

Calgary, Alberta, Canada

Principal Use

Institutional

Design Architect

DIALOG

Anything about the engineers? Facade consultants?

DIALOG and Transsolar Klimaengineering

Gross Floor Area

22,976 m2 Units SI IP

247,314 ft2

Reason(s) for inclusion

Building Name

The University of Calgary - MacKimmie Tower

Address

2500 University Drive NW, Calgary Alberta Canada

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

Designed by DIALOG, the MacKimmie Tower Redevelopment is both a respectful homage to the original 1960s tower and a very contemporary reimagination of it. . DIALOG’s design for the MacKimmie Complex redevelopment enhances the overall campus identity by creating a clear and cohesive architectural complex at the heart of the University. In response, the design uses dynamic double skin façade creating diagonal lines first inside face of the columns and the second skin with the at the outside face of the columns. The façade’s diagonal angles read the transference of light as it moves throughout.

General Information

Year completed (or major renovation)

2020

Construction Cost

86,700,000.00

Climate Zone

Continental

Building Certifications (check all that apply)

  • LEED
  • CaGBC Net Zero Carbon Certification

External Links

Link(s) for more information

Other Design Features

Energy Performance

Energy Use Intensity (energy consumption per year)

75 kWh/m2/year

808 kBtu/ft2/year

Percentage Provided by On-site Renewables

23

Construction Type

Construction Type: Other

Ventilated Double Skin Façade

Prevalent Glazing Type

  • triple glazing

Main Cladding Material

  • Glass
  • Aluminum
  • Steel
  • Concrete

Approximate WWR (measured from the inside)

100%

Typical U-value Glazed Facade Elements

1 W/(m2⋅K)

0 Btu/(h·ft2⋅F)

Typical G-value Glazed Facade Elements

50%

Typical VLT Glazed Facade Elements

70%

Typical U-value Solid Facade Elements

0.26 W/(m2⋅K)

0.05 Btu/(h·ft2⋅F)

Skin Type

Skin Type

  • Double Skin Facade

Geometrical configuration

  • Corridor
  • Shaft
  • Multi-storey

Ventilation type

  • Open Cavity

Solar Shading

Solar Shading Strategy

  • Glazing-integrated Shading

Ventilation

Is there natural ventilation through the facade?

Yes

Type of Ventilation Strategy

  • Double sided
  • Stack or Atrium-enabled

Relationship to Mechanical Systems

  • Assisted (both can work simultaneously)

Ventilation Operation Type

  • Manual
  • BMS controlled with overrides

Ventilation Control Strategy

  • Based on Both
  • Temperature, Humidity , Weather, and Pressure measurement telemetry
  • Other (please specify)
  • Temperature, Humidity , Weather, and Pressure measurement telemetry

Area of the building that can be served solely by natural ventilation

40%

Daylight

Is daylight simulation part of the design process?

No

Noise

Embodied Carbon

Was a carbon assesment of the facade conducted in the design phase?

No

Energy Generation

Does the facade produce energy?

No

Type of Energy Produced

  • Electrical

Insulation

Does the facade have a dynamic U-value?

No

Monomaterial envelope?

No

Description / Additional Information