CBE Facade Map

Supporting the adoption of advanced facade design strategies and technologies

Select Page

Map

Shareable post

Sonoma Academy

Location

Santa Rosa, CA, United States

Principal Use

Cultural

Design Architect

WRNS Studio

Anything about the engineers? Facade consultants?

Interface Engineering, Inc.

Gross Floor Area

1,766 m2 Units SI IP

19,000 ft2

Reason(s) for inclusion

Building Name

Sonoma Acadamy Building

Address

2500 Farmers Ln, Santa Rosa, CA 95404, United States

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

Embedded with maker/digital classrooms, productive gardens, offices and a full dining/kitchen, Sonoma Academy’s guiding principles of equity, community, and exploration inspired the Guild & Commons two sweeping floors, which stretch to views and integrate into the land. Sliding screens, automated shades, deep overhangs relay how the building responds to climate. Regionally sourced low carbon block, ceramic tiles, reclaimed beams, exterior and interior siding, pair with regionally made lamps and furniture to celebrate community. The living roof attracts pollinators, houses photovoltaics.

General Information

Year completed (or major renovation)

2018

Construction Cost

17000000

Climate Zone

Temperate

Building Certifications (check all that apply)

  • LEED
  • Well
  • LBC Petal

Other Design Features

Energy Performance

Energy Use Intensity (energy consumption per year)

-0 kWh/m2/year

-4 kBtu/ft2/year

Percentage Provided by On-site Renewables

80

Construction Type

Construction Type

  • Curtain Wall
  • Modular Facade

Prevalent Glazing Type

  • Triple Glazing
  • Other (please specify)

Main Cladding Material

  • Glass
  • Steel

Skin Type

Skin Type

  • Single Skin Facade

Solar Shading

Solar Shading Strategy

  • Dynamic Exterior Shading
  • Manual Moveable Shades

Exterior shading

  • Custom Movable Elements

Glazing-integrated shading

  • Other (please specify)

Ventilation

Is there natural ventilation through the facade?

Yes

Type of Ventilation Strategy

  • Single-sided

Relationship to Mechanical Systems

  • Exclusive (no mechanical ventilation is possible)

Ventilation Operation Type

  • Manual

Daylight

Is daylight simulation part of the design process?

Yes

Daylight metric(s)

  • Other (please specify)

Target value(s)

100

Achieved value(s)

Noise

Embodied Carbon

Was a carbon assesment of the facade conducted in the design phase?

Yes

Facade embodied carbon intensity

4 kgCO2e/m2

39 kgCO2e/ft2

Energy Generation

Does the facade produce energy?

No

Insulation

Description / Additional Information