CBE Facade Map

Supporting the adoption of advanced facade design strategies and technologies

Select Page

Map

Shareable post

Manitoba Hydro Place

Location

Winnipeg, Manitoba, Canada

Principal Use

Office

Design Architect

KPMB Architects (Kuwabara Payne McKenna Blumberg); Smith Carter Architects and Engineers (architect of record)

Anything about the engineers? Facade consultants?

Transsolar KlimaEngineering (energy/climate); Brook Van Dalen & Associates (building envelope)

Gross Floor Area

64,591 m2 Units SI IP

695,258 ft2

Reason(s) for inclusion

Building Name

Manitoba Hydro Place

Address

360 Portage Avenue, Winnipeg, MB R3C 0G8, Canada

Description / Additional Information

Describe the key innovation and technology aspects of the project

Project Narrative

A multi-storey double-skin facade with a 1-metre-wide buffer cavity conditions incoming air before it enters the HVAC system—critical in Winnipeg's extreme continental climate (-35°C to +35°C). A 22-storey solar chimney draws warm air upward for passive cooling in summer. The south facade uses automated exterior shading; the north relies on the insulating buffer cavity. First LEED Platinum office building in North America. EUI: 85 kWh/m²/year.

General Information

Year completed (or major renovation)

2009

Construction Cost

235000000

Climate Zone

Continental

Building Certifications (check all that apply)

  • LEED
  • LEED Platinum (first large Canadian office tower, 2011)

External Links

Link(s) for more information

Other Design Features

Energy Performance

Construction Type

Construction Type

  • Frame Facade Construction

Prevalent Glazing Type

  • Double Glazing

Main Cladding Material

  • Glass

Skin Type

Skin Type

  • Double Skin Facade

Geometrical configuration

  • Multi-storey

Ventilation type

  • Open Cavity

Solar Shading

Solar Shading Strategy

  • Dynamic Exterior Shading

Exterior shading

  • Exterior Movable Louvers or Blinds

Ventilation

Is there natural ventilation through the facade?

Yes

Type of Ventilation Strategy

  • Stack or Atrium-enabled

Daylight

Is daylight simulation part of the design process?

Yes

Noise

Embodied Carbon

Energy Generation

Insulation

Description / Additional Information