Project Narrative
The north and west facades use a multi-system active envelope: computer-controlled hydraulic timber louvers made of recycled hardwood track solar angles throughout the day. The west face features precast concrete blade fins for thermal mass shading, and the east face uses perforated metal screens. The integrated facade strategy reduced energy use by 87% versus a standard building. First to achieve 6-Star Green Star in Australia.
General Information
Year completed (or major renovation)
2006
Construction Cost
38000000
Climate Zone
Temperate
Building Certifications (check all that apply)
- Green Star (Australia)
- Green Star 6-Star Office Design v1 — Australia's first
Other Design Features
Energy Performance
Construction Type
Construction Type
- Frame Facade Construction
Prevalent Glazing Type
- Double Glazing
Main Cladding Material
- Other (please specify)
Skin Type
Skin Type
- Another skin
Solar Shading
Solar Shading Strategy
- Static Exterior Shading
Ventilation
Is there natural ventilation through the facade?
Yes
Type of Ventilation Strategy
- Stack or Atrium-enabled
Daylight
Is daylight simulation part of the design process?
Yes